Ultramar Water · Fouling Resistant
FR-8040-400 (34)-ULTRAMAR-WATER
FR-8040-400(34) fouling resistant reverse osmosis membrane The FR-8040-400(34) is an 8-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life […]
- Diametro
- 8″
- Formato
- 8040
FR-8040-400(34) fouling resistant reverse osmosis membrane
The FR-8040-400(34) is an 8-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life under difficult water conditions. Key operational data includes a permeate flow of 10,500 GPD (40 m³/day), an active membrane area of 400 ft² (37 m²), and a stabilized salt rejection of 99.6%.
Specifications
| Model | Permeate Flow GPD (m³/day) | Active Membrane Area ft² (m²) | Stabilized Salt Rejection | Minimum Salt Rejection | Feed Spacer mil (mm) | Test Conditions |
|---|---|---|---|---|---|---|
| FR-8040-400(34) | 10,500 (40) | 400 (37) | 99.6% | 99.4% | 34 (0.85) | 225 psi / 2,000 ppm NaCl |
Dimensions
| Model | A | B | C |
|---|---|---|---|
| FR-8040-400(34) | 40.0 (1016) | 1.125 (29) | 7.9 (201) |
Operating limits for design
| Maximum Operating Temperature | 45°C (113°F) |
| Maximum Operating Pressure | 600 psi (41 bar) |
| Maximum Pressure Drop (single element) | 15 psi (1.0 bar) |
| pH Range for Continuous Operation | 2–11 |
| pH Range for Cleaning | 1.2–12 |
| Chlorine Tolerance | < 0.1 ppm |
| Maximum Feed SDI | 5 |
Important operation notes
- Discard the permeate produced during the first hour of use.
- Keep elements moist at all times after initial wetting.
- During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
- The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
- Failure to follow these operating limits voids the limited warranty.
Private label and custom versions
The FR-8040-400(34) is available under your brand. Contact our team for volumes, labeling and custom specifications.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.
Membrane simili