FR-4040 fouling resistant reverse osmosis membrane The FR-4040 is a 4-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life […]

Diametro
4″
Formato
4040

FR-4040 fouling resistant reverse osmosis membrane

The FR-4040 is a 4-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life under difficult water conditions. Key operational data includes a permeate flow of 2,400 GPD (9 m³/day), an active membrane area of 90 ft² (8.4 m²), and a stabilized salt rejection of 99.6%.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
FR-40402,400 (9)90 (8.4)99.6%99.4%28 (0.7)225 psi / 2,000 ppm NaCl
1. All performance data are collected at 25°C (77°F), pH 7.5 and 8% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelOverall Length (A)Permeate Tube Extension (B)Diameter (C)
FR-404040.0 (1016)1.05 (26.7)3.9 (99)
Dimensions in inches (mm). 1 inch = 25.4 mm. Permeate tube diameter is 0.75 in (19 mm).

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation2–11
pH Range for Cleaning1.2–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The FR-4040 is available under your brand. Contact our team for volumes, labeling and custom specifications.