Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italien +39 0721 1797741 info@ultramarwater.com
FR-8040-400 (34)-ULTRAMAR-WATER

Ultramar Water · Fouling Resistant

FR-8040-400 (34)-ULTRAMAR-WATER

FR-8040-400(34) fouling resistant reverse osmosis membrane The FR-8040-400(34) is an 8-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life […]

Durchmesser
8″
Format
8040

FR-8040-400(34) fouling resistant reverse osmosis membrane

The FR-8040-400(34) is an 8-inch spiral wound fouling resistant reverse osmosis membrane, specifically designed for water treatment applications prone to biological and organic fouling. Thanks to a special surface treatment that makes it more hydrophilic, it allows effective cleaning and renewal of the active surface, extending its service life under difficult water conditions. Key operational data includes a permeate flow of 10,500 GPD (40 m³/day), an active membrane area of 400 ft² (37 m²), and a stabilized salt rejection of 99.6%.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
FR-8040-400(34)10,500 (40)400 (37)99.6%99.4%34 (0.85)225 psi / 2,000 ppm NaCl
1. All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelABC
FR-8040-400(34)40.0 (1016)1.125 (29)7.9 (201)
Dimensions in inches (mm). 1 inch = 25.4 mm.

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation2–11
pH Range for Cleaning1.2–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The FR-8040-400(34) is available under your brand. Contact our team for volumes, labeling and custom specifications.

Benötigen Sie diese Membran für Ihre Anlage?

Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.

Angebot anfordern

Ähnliche Membranen

Adresse

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italien