Filmtec · Brackish Water
BW30XFRLE-400/34
DuPont™ FilmTec™ BW30XFRLE-400/34 Brackish Water Reverse Osmosis Element The DuPont™ FilmTec™ BW30XFRLE-400/34 brackish water reverse osmosis element is designed with fouling-resistant and low-energy features, offering up to 30% lower energy consumption than standard-pressure RO elements and excellent rejection of silica, nitrates, ammonium and per- and polyfluoroalkyl substances (PFAS). Key specifications include an active area of […]
- Diametro
- 8″
- Formato
- 8040
DuPont™ FilmTec™ BW30XFRLE-400/34 Brackish Water Reverse Osmosis Element
The DuPont™ FilmTec™ BW30XFRLE-400/34 brackish water reverse osmosis element is designed with fouling-resistant and low-energy features, offering up to 30% lower energy consumption than standard-pressure RO elements and excellent rejection of silica, nitrates, ammonium and per- and polyfluoroalkyl substances (PFAS). Key specifications include an active area of 400 ft² (37 m²), a permeate flow rate of 11,500 GPD (43.5 m³/d) and a stabilized salt rejection of 99.3%.
Specifications
| Feature | Value / Technical data |
|---|---|
| Active area | 400 ft² (37 m²) |
| Feed spacer thickness | 34-LDP |
| Permeate flow rate | 11,500 GPD (43.5 m³/d) |
| Stabilized salt rejection | 99.3% |
| Minimum salt rejection | 99.1% |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 40.0 in | 1,016 mm |
| B DIA | 7.9 in | 201 mm |
| C DIA (ID) | 1.125 in ID | 29 mm ID |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 600 psi (41 bar) |
| Maximum pressure drop per element | 15 psi (1.0 bar) |
| Maximum pressure drop per pressure vessel (minimum 4 elements) | 50 psi (3.5 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum feed flow rate | 75 gpm (17 m³/h) |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty.
- Discard the permeate obtained during the first hour of operation.
- Use of this product does not by itself guarantee the removal of cysts and pathogens from water; effectiveness depends on overall system design and maintenance.
Private label and custom versions
The DuPont™ FilmTec™ BW30XFRLE-400/34 element is ideal for municipal drinking water, municipal and industrial wastewater reuse, and industrial process water applications. Contact our team for commercial inquiries, customization options and technical support.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.
Membrane simili