Ultramar Water · Sea Water
SW-4040-HR-ULTRAMAR-WATER
SW-4040-HR Sea Water RO Membrane The SW-4040-HR sea water RO membrane is designed for high-pressure seawater treatment applications requiring high salt rejection and productivity. It features a stabilized salt rejection of 99.8% and a minimum salt rejection of 99.7%. This membrane element is intended for OEMs, seawater treatment system builders and technical service centers looking […]
- Diameter
- 4″
- Format
- 4040
SW-4040-HR Sea Water RO Membrane
The SW-4040-HR sea water RO membrane is designed for high-pressure seawater treatment applications requiring high salt rejection and productivity. It features a stabilized salt rejection of 99.8% and a minimum salt rejection of 99.7%. This membrane element is intended for OEMs, seawater treatment system builders and technical service centers looking for components for seawater reverse osmosis systems.
Ultramar Water supplies membrane elements for seawater treatment applications, supporting system builders and industrial water treatment professionals in selecting components according to their system design and operating requirements. The SW-4040-HR is an option to consider for high-pressure seawater treatment systems where salt rejection is a key selection criterion.
Specifications
| Model | Permeate Flow GPD (m³/day) | Active Membrane Area ft² (m²) | Stabilized Salt Rejection | Minimum Salt Rejection | Feed Spacer mil (mm) | Test Conditions |
|---|---|---|---|---|---|---|
| SW-4040-HR | 1,400 (5.3) | 90 (8.4) | 99.8% | 99.7% | 28 (0.7) | 800 psi / 32,800 ppm NaCl |
Dimensions
| Model | A | B | C | D |
|---|---|---|---|---|
| SW-4040-HR | 40.0 (1016) | 1.05 (26.7) | 0.75 (19) | 3.9 (99) |
Operating limits for design
| Maximum Operating Temperature | 45°C (113°F) |
| Maximum Operating Pressure | 1200 psi (83 bar) |
| Maximum Pressure Drop (single element) | 15 psi (1.0 bar) |
| pH Range for Continuous Operation | 2–11 |
| pH Range for Cleaning | 1.2–12 |
| Chlorine Tolerance | < 0.1 ppm |
| Maximum Feed SDI | 5 |
Important operation notes
- Discard the permeate produced during the first hour of use.
- Keep elements moist at all times after initial wetting.
- During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
- The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
- Failure to follow the applicable operating limits and guidelines may affect the product warranty.
Private label and custom versions
The SW-4040-HR sea water RO membrane can be evaluated for private label supply and customized requirements. Contact our team to discuss volumes, labeling and custom specifications.
Need this membrane in your system?
We can adapt it to your plant, label it with your brand and support you through installation.