Filmtec · Sea Water
SW30XLE-440
DuPont™ FilmTec™ SW30XLE-440 Seawater Reverse Osmosis Element The DuPont™ FilmTec™ SW30XLE-440 seawater reverse osmosis element ensures a low total cost of water by optimizing system energy consumption and productivity, helping to reduce capital costs by maximizing production capacity. It is ideal for municipal and industrial desalination plants with medium or high salinity. Key specifications include […]
- Diameter
- 8″
- Format
- 8040
DuPont™ FilmTec™ SW30XLE-440 Seawater Reverse Osmosis Element
The DuPont™ FilmTec™ SW30XLE-440 seawater reverse osmosis element ensures a low total cost of water by optimizing system energy consumption and productivity, helping to reduce capital costs by maximizing production capacity. It is ideal for municipal and industrial desalination plants with medium or high salinity. Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 9,900 gpd (37.4 m³/d) and a stabilized salt rejection of 99.8%.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Active area | 440 ft² (41 m²) |
| Feed spacer thickness | 28 mil |
| Permeate flow rate | 9,900 gpd (37.4 m³/d) |
| Stabilized boron rejection | 91.5% |
| Stabilized salt rejection | 99.8% |
| Minimum salt rejection | 99.6% |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 40.0 in | 1,016 mm |
| Diameter (B) | 7.9 in | 201 mm |
| Inner diameter (C) | 1.125 in ID | 29 mm ID |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 1,200 psi (83 bar) |
| Maximum pressure drop per element | 15 psi (1.0 bar) |
| Maximum pressure drop per pressure vessel (minimum 4 elements) | 50 psi (3.5 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum Silt Density Index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered under warranty.
- Permeate obtained from the first hour of operation should be discarded.
- Use of this product does not in itself guarantee the removal of cysts and pathogens from water; effectiveness depends on the overall system design and maintenance.
Private label and custom versions
The DuPont™ FilmTec™ SW30XLE-440 element can be integrated into desalination systems for high-productivity, low-energy municipal and industrial applications. Contact our team for commercial inquiries, customization options and technical support.
Need this membrane in your system?
We can adapt it to your plant, label it with your brand and support you through installation.