Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
NF-8040-400-HF-34-ULTRAMAR-WATER

Ultramar Water · Nano Filtration

NF-8040-400-HF-34-ULTRAMAR-WATER

NF-8040-400-HF(34) nanofiltration membrane The NF-8040-400-HF(34) is an 8-inch spiral wound nanofiltration element designed for low-pressure applications. Offering high productivity and selectivity for water treatment, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational data includes a permeate flow of 7,900 GPD (30 m³/day) with MgSO₄ and 9,500 GPD […]

Diametro
8″
Formato
8040

NF-8040-400-HF(34) nanofiltration membrane

The NF-8040-400-HF(34) is an 8-inch spiral wound nanofiltration element designed for low-pressure applications. Offering high productivity and selectivity for water treatment, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational data includes a permeate flow of 7,900 GPD (30 m³/day) with MgSO₄ and 9,500 GPD (36 m³/day) with NaCl, an active membrane area of 400 ft² (37 m²), and a stabilized salt rejection of 95% (MgSO₄) and 15–20% (NaCl).

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
NF-8040-400-HF(34)7,900 (30)400 (37)95%93%34 (0.85)30 psi / 2,000 ppm MgSO₄
NF-8040-400-HF(34)9,500 (36)400 (37)15–20%15–20%34 (0.85)30 psi / 500 ppm NaCl
1. All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelABC
NF-8040-400-HF(34)40.0 (1016)1.125 (29)7.9 (201)
Dimensions in inches (mm). 1 inch = 25.4 mm.

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation3–10
pH Range for Cleaning2–11
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The NF-8040-400-HF(34) is available under your brand. Contact our team for volumes, labeling and custom specifications.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Membrane simili

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia