Ultramar Water · Nano Filtration
NF-4040-HR-ULTRAMAR-WATER
NF-4040-HR nanofiltration membrane – Low pressure, high productivity The NF-4040-HR nanofiltration membrane from Ultramar Water is a 4″ spiral wound membrane element designed for low-pressure nanofiltration applications requiring high productivity. With an active membrane area of 90(8.4) ft²(m²), a permeate flow of 2100(8) GPD(m³/day) and a stabilized salt rejection of 99% under MgSO4 test conditions, […]
- Diametro
- 4″
- Formato
- 4040
NF-4040-HR nanofiltration membrane – Low pressure, high productivity
The NF-4040-HR nanofiltration membrane from Ultramar Water is a 4″ spiral wound membrane element designed for low-pressure nanofiltration applications requiring high productivity.
With an active membrane area of 90(8.4) ft²(m²), a permeate flow of 2100(8) GPD(m³/day) and a stabilized salt rejection of 99% under MgSO4 test conditions, the NF-4040-HR is suitable for OEMs, water treatment system builders and service centres looking for nanofiltration elements for new installations or membrane replacement.
Specifications
| Model | Permeate Flow GPD(m³/day) | Active Membrane Area ft²(m²) | Stabilized Salt Rejection | Minimum Salt Rejection | Feed spacer mil(mm) | Test Conditions |
|---|---|---|---|---|---|---|
| NF-4040-HR | 2100(8) | 90(8.4) | 99% | 98% | 28(0.7) | 100psi/2000ppm MgSO4 |
| 2000(8) | 40~60% | 40~60% | 70psi/500ppm NaCl |
2. Permeate flows for single element may vary ±15%.
Dimensions
| Model | Overall length | Feed-end tube extension | Product-end tube extension | Permeate tube diameter | Element outer diameter |
|---|---|---|---|---|---|
| NF-4040-HR | 40.0(1016) | 1.05(26.7) | 1.05(26.7) | 0,75(19) | 3,9(99) |
1 inch= 25.4 mm
Operating limits for design
| Maximum Operating Temperature | 45°C(113°F) |
| Maximum Operating Pressure | 600psi(41bar) |
| Maximum Pressure Drop (single element) | 15psi(1.0bar) |
| pH Range for Continuous Operation | 3-10 |
| pH Range for Cleaning | 2-11 |
| Chlorine tolerance | <0.1ppm |
| Maximum Feed SDI | 5 |
Important operation notes
- Discard the permeate produced during the first hour of use.
- Keep elements moist at all times after initial wetting.
- During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
- The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
- Failure to follow these operating limits voids the limited warranty.
Private label and custom versions
The NF-4040-HR is available under your brand. Contact our team for volumes, labeling and custom specifications.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.
Membrane simili