Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
XUS180804

Filmtec · Process

XUS180804

DuPont™ Specialty Membrane XUS180804 and XUS180802 Ultra-High-Pressure Reverse Osmosis Elements DuPont™ Specialty Membrane XUS180804 and XUS180802 ultra-high-pressure reverse osmosis elements are designed for industrial water purification and offer feed pressure capability up to 120 bar (1,740 psi). They increase the overall efficiency of Zero Liquid Discharge (ZLD) systems by reaching very high solute concentrations and […]

DuPont™ Specialty Membrane XUS180804 and XUS180802 Ultra-High-Pressure Reverse Osmosis Elements

DuPont™ Specialty Membrane XUS180804 and XUS180802 ultra-high-pressure reverse osmosis elements are designed for industrial water purification and offer feed pressure capability up to 120 bar (1,740 psi). They increase the overall efficiency of Zero Liquid Discharge (ZLD) systems by reaching very high solute concentrations and reducing the size of downstream thermal treatment. Features include a 34 mil feed spacer to reduce the impact of fouling and a robust membrane sheet.

Specifications

FeatureXUS180804XUS180802
Active area73 ft² (6.8 m²)22 ft² (2.0 m²)
Feed spacer thickness34 mil34 mil
Minimum ATD outer diameter3.9 in2.5 in
ATD includedYesYes
Membrane typeFilmTec™ RO membrane sheet
General specifications of the XUS180804 and XUS180802 elements.

Dimensions

DimensionXUS180804XUS180802
Length (A)40.0 in (1,016 mm)40.0 in (1,016 mm)
B1.03 in (26 mm)1.03 in (26 mm)
C DIA0.75 in OD (19 mm OD)0.75 in OD (19 mm OD)
D DIA3.9 in (99 mm)2.4 in (63.5 mm)
Dimensions in inches (mm). 1 inch = 25.4 mm.

Operating limits for design

Maximum operating temperature113°F (45°C)
Maximum operating pressure (up to 30°C)1,740 psig (120 bar)
Maximum pressure drop per element15 psig (1.0 bar)
pH range (continuous operation)2–11
pH range (short-term cleaning, 30 min)1–13
Maximum feed silt density index (SDI)SDI 5
Free chlorine tolerance< 0.1 ppm

Important operation notes

  • Maximum feed pressure depends on temperature: 120 bar (1,740 psi) from 5°C to 30°C, decreasing to 103 bar (1,494 psi) at 35°C, 90 bar (1,305 psi) at 40°C and 83 bar (1,200 psi) at 45°C.
  • The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Avoid abrupt changes in pressure or crossflow during start-up, shutdown or cleaning to prevent membrane damage.
  • Keep elements moist at all times after initial wetting, and immerse them in a preservative solution during prolonged plant shutdowns.
  • Discard any concentrate or permeate obtained during the first hour of operation.

Private label and custom versions

DuPont™ Specialty Membrane XUS180804 and XUS180802 elements are ideal for salt recovery from process streams and for advanced industrial water purification and ZLD applications. Contact our team for commercial inquiries, customization options and technical support.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Membrane simili

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia