DuPont™ IntegraTec™ XP 51 PVDF Ultrafiltration Module The DuPont™ IntegraTec™ XP 51 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2860XP) from the P Series uses advanced XP™ hydrophilic PVDF fiber technology, providing superior fouling and chlorine resistance, excellent permeability and high removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on custom […]

DuPont™ IntegraTec™ XP 51 PVDF Ultrafiltration Module

The DuPont™ IntegraTec™ XP 51 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2860XP) from the P Series uses advanced XP™ hydrophilic PVDF fiber technology, providing superior fouling and chlorine resistance, excellent permeability and high removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on custom skids, it is ideal for containerized or height-restricted installations. Key specifications include an active membrane area of 51 m² (549 ft²) and a nominal pore size of approximately 0.03 μm.

Specifications

FeatureValue / Technical Data
Part No / GMID12091625
Filtration modeOut-In Pressurized
Membrane typeHollow fiber
Membrane materialPVDF (Polyvinylidene Fluoride)
Nominal pore sizeApprox. 0.03 μm
Module operating processDead-end
Other wetted componentsPolyurethane, polyethylene and polyamide
Active membrane area51 m² (549 ft²)
General specifications of the XP 51 module.

Dimensions

DimensionMetricImperial
Overall module length (L)1,863 ± 3.0 mm73.3 ± 0.1 in
Module length (L1)1,500 ± 1.5 mm59.1 ± 0.1 in
Module length (L2)1,633 ± 3.0 mm64.3 ± 0.1 in
Module length (L3)1,823 ± 3.0 mm71.8 ± 0.1 in
Module diameter (D)225 mm8.9 in
Module width (W1)180 mm7.1 in
Module width (W2)342 mm13.5 in
Feed / filtrate port DN50 (F)51 mm2.0 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1–40°C (34–104°F)
Operating pH2–11
Cleaning pH2–12
Maximum inlet pressure6.25 bar at 20°C (90.7 psi)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
NaOCl exposure (free chlorine tolerance)≤ 1,500,000 ppm×h

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ PVDF-UF Out-In P Series Modules for Open Platforms Assembly Manual (Form No. 45-D02507-en).
  • During prolonged system shutdowns, introduce a preservation solution to control biological growth.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ XP 51 module can be integrated into customized open-platform solutions for high-recovery applications. Contact our team for commercial inquiries, customization options and technical support.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia