Integratec
XP-51
DuPont™ IntegraTec™ XP 51 PVDF Ultrafiltration Module The DuPont™ IntegraTec™ XP 51 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2860XP) from the P Series uses advanced XP™ hydrophilic PVDF fiber technology, providing superior fouling and chlorine resistance, excellent permeability and high removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on custom […]
DuPont™ IntegraTec™ XP 51 PVDF Ultrafiltration Module
The DuPont™ IntegraTec™ XP 51 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2860XP) from the P Series uses advanced XP™ hydrophilic PVDF fiber technology, providing superior fouling and chlorine resistance, excellent permeability and high removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on custom skids, it is ideal for containerized or height-restricted installations. Key specifications include an active membrane area of 51 m² (549 ft²) and a nominal pore size of approximately 0.03 μm.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Part No / GMID | 12091625 |
| Filtration mode | Out-In Pressurized |
| Membrane type | Hollow fiber |
| Membrane material | PVDF (Polyvinylidene Fluoride) |
| Nominal pore size | Approx. 0.03 μm |
| Module operating process | Dead-end |
| Other wetted components | Polyurethane, polyethylene and polyamide |
| Active membrane area | 51 m² (549 ft²) |
Dimensions
| Dimension | Metric | Imperial |
|---|---|---|
| Overall module length (L) | 1,863 ± 3.0 mm | 73.3 ± 0.1 in |
| Module length (L1) | 1,500 ± 1.5 mm | 59.1 ± 0.1 in |
| Module length (L2) | 1,633 ± 3.0 mm | 64.3 ± 0.1 in |
| Module length (L3) | 1,823 ± 3.0 mm | 71.8 ± 0.1 in |
| Module diameter (D) | 225 mm | 8.9 in |
| Module width (W1) | 180 mm | 7.1 in |
| Module width (W2) | 342 mm | 13.5 in |
| Feed / filtrate port DN50 (F) | 51 mm | 2.0 in |
Operating limits for design
| Operating temperature range | 1–40°C (34–104°F) |
| Operating pH | 2–11 |
| Cleaning pH | 2–12 |
| Maximum inlet pressure | 6.25 bar at 20°C (90.7 psi) |
| Maximum allowable pressure change rate | 0.5 bar/s (7.3 psi/s) |
| NaOCl exposure (free chlorine tolerance) | ≤ 1,500,000 ppm×h |
Important operation notes
- Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
- For assembly, refer to the dedicated DuPont™ IntegraTec™ PVDF-UF Out-In P Series Modules for Open Platforms Assembly Manual (Form No. 45-D02507-en).
- During prolonged system shutdowns, introduce a preservation solution to control biological growth.
- Modules certified for drinking water require specific conditioning procedures before production.
- Failure to strictly follow the operating limits and guidelines voids any warranty.
Private label and custom versions
The DuPont™ IntegraTec™ XP 51 module can be integrated into customized open-platform solutions for high-recovery applications. Contact our team for commercial inquiries, customization options and technical support.