DuPont™ IntegraTec™ MB 25 Pressurized Ultrafiltration Module The DuPont™ IntegraTec™ MB 25 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 25 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance. Designed for open-platform applications on custom skids, it delivers high removal of colloidal particulates, bacteria […]

DuPont™ IntegraTec™ MB 25 Pressurized Ultrafiltration Module

The DuPont™ IntegraTec™ MB 25 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 25 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance. Designed for open-platform applications on custom skids, it delivers high removal of colloidal particulates, bacteria and viruses. Key specifications include an active membrane area of 25 m² (269 ft²) and a nominal membrane pore size of 0.02 μm.

Specifications

FeatureValue / Technical Data
Part Number / GMIDIN-0071/12071519
Filtration modeIn-Out Pressurized
Membrane typeMultibore
Membrane materialPESM
Nominal pore size0.02 μm
Module operating processDead-end
Housing materialPVC-U, white
Active membrane area25 m² (269 ft²)
General specifications of the MB 25 module.

Dimensions

DimensionMetricImperial
Module length (L)985 ± 15 mm38.8 in
Distance between top/bottom feed ports (L1)1,099 ± 3.0 mm43.3 in
Length with end caps (L2)1,179 ± 3.0 mm46.4 in
Module diameter (A)250 ± 1.5 mm9.8 in
Distance from top feed port to filtrate port (B)190 ± 1.5 mm7.5 in
Maximum end cap coupling outer diameter (C)295 mm11.6 in
Filtrate / backwash port (D)50.8 mm2 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1–40°C (34–104°F)
Operating pH3–11
Cleaning pH1–13
Maximum inlet pressure5 bar (73 psi)
Maximum temperature change rate5°C/min (9°F/min)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
NaOCl exposure (free chlorine tolerance)≤ 250,000 ppm×h (at pH ≥ 9.5)

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage.
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ Pressurized UF In-Out P Series Modules for Open Platforms Assembly Instructions (Form No. 45-D02231-en).
  • During prolonged system shutdowns, introduce a preservation solution to control biological growth, following the dedicated manual.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ MB 25 module can be integrated into customized open-platform solutions. Contact our team for commercial inquiries, customization options and technical support.