MB-25

DuPont™ IntegraTec™ MB 25 Pressurized Ultrafiltration Module The DuPont™ IntegraTec™ MB 25 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 25 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance. Designed for open-platform applications on custom skids, it delivers high removal of colloidal particulates, bacteria […]

DuPont™ IntegraTec™ MB 25 Pressurized Ultrafiltration Module

The DuPont™ IntegraTec™ MB 25 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 25 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance. Designed for open-platform applications on custom skids, it delivers high removal of colloidal particulates, bacteria and viruses. Key specifications include an active membrane area of 25 m² (269 ft²) and a nominal membrane pore size of 0.02 μm.

Specifications

FeatureValue / Technical Data
Part Number / GMIDIN-0071/12071519
Filtration modeIn-Out Pressurized
Membrane typeMultibore
Membrane materialPESM
Nominal pore size0.02 μm
Module operating processDead-end
Housing materialPVC-U, white
Active membrane area25 m² (269 ft²)
General specifications of the MB 25 module.

Dimensions

DimensionMetricImperial
Module length (L)985 ± 15 mm38.8 in
Distance between top/bottom feed ports (L1)1,099 ± 3.0 mm43.3 in
Length with end caps (L2)1,179 ± 3.0 mm46.4 in
Module diameter (A)250 ± 1.5 mm9.8 in
Distance from top feed port to filtrate port (B)190 ± 1.5 mm7.5 in
Maximum end cap coupling outer diameter (C)295 mm11.6 in
Filtrate / backwash port (D)50.8 mm2 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1–40°C (34–104°F)
Operating pH3–11
Cleaning pH1–13
Maximum inlet pressure5 bar (73 psi)
Maximum temperature change rate5°C/min (9°F/min)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
NaOCl exposure (free chlorine tolerance)≤ 250,000 ppm×h (at pH ≥ 9.5)

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage.
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ Pressurized UF In-Out P Series Modules for Open Platforms Assembly Instructions (Form No. 45-D02231-en).
  • During prolonged system shutdowns, introduce a preservation solution to control biological growth, following the dedicated manual.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ MB 25 module can be integrated into customized open-platform solutions. Contact our team for commercial inquiries, customization options and technical support.

Benötigen Sie diese Membran für Ihre Anlage?

Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.

Angebot anfordern

Adresse

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italien