Filmtec · Extra Low Energy
XLE-2521
DuPont™ FilmTec™ XLE-2521 Reverse Osmosis Element The DuPont™ FilmTec™ XLE-2521 reverse osmosis element is part of the brackish water element range for small commercial systems and is designed with extra low energy technology, operating at the industry’s lowest pressure to reduce energy costs. Key specifications include a permeate flow rate of 365 GPD (1.38 m³/d) […]
- Diametro
- 2,5″
- Formato
- 2521
DuPont™ FilmTec™ XLE-2521 Reverse Osmosis Element
The DuPont™ FilmTec™ XLE-2521 reverse osmosis element is part of the brackish water element range for small commercial systems and is designed with extra low energy technology, operating at the industry’s lowest pressure to reduce energy costs. Key specifications include a permeate flow rate of 365 GPD (1.38 m³/d) and a stabilized salt rejection of 99.0%.
Specifications
| Feature | Value / Technical data |
|---|---|
| Part number | 154530 |
| Permeate flow rate | 365 GPD (1.38 m³/d) |
| Applied pressure | 100 psi (6.9 bar) |
| Stabilized salt rejection | 99.0% |
| Maximum feed flow rate | 6 gpm (1.4 m³/h) |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 21.0 in | 533 mm |
| Diameter (B) | 2.4 in | 61 mm |
| Permeate tube diameter (C) | 0.75 in | 19 mm |
| D | 1.05 in | 26.7 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 600 psi (41 bar) |
| Maximum pressure drop per element | 13 psi (0.9 bar) |
| Maximum pressure drop per pressure vessel (maximum 2 elements) | 30 psi (2.1 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty; pretreatment to remove free chlorine is recommended.
- Discard the permeate obtained during the first hour of operation.
- Use of this product does not by itself guarantee the removal of cysts and pathogens from water.
Private label and custom versions
The DuPont™ FilmTec™ XLE-2521 element is ideal for small commercial systems that require very low pressure operation and reduced energy consumption. Contact our team for commercial inquiries, customization options and technical support.
DuPont™ FilmTec™ XLE-2521 Reverse Osmosis Element
The DuPont™ FilmTec™ XLE-2521 reverse osmosis element is part of the brackish water element range for small commercial systems and is designed with extra low energy technology, operating at the industry’s lowest pressure to reduce energy costs. Key specifications include a permeate flow rate of 365 GPD (1.38 m³/d) and a stabilized salt rejection of 99.0%.
Specifications
| Feature | Value / Technical data |
|---|---|
| Part number | 154530 |
| Permeate flow rate | 365 GPD (1.38 m³/d) |
| Applied pressure | 100 psi (6.9 bar) |
| Stabilized salt rejection | 99.0% |
| Maximum feed flow rate | 6 gpm (1.4 m³/h) |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 21.0 in | 533 mm |
| Diameter (B) | 2.4 in | 61 mm |
| Permeate tube diameter (C) | 0.75 in | 19 mm |
| D | 1.05 in | 26.7 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 600 psi (41 bar) |
| Maximum pressure drop per element | 13 psi (0.9 bar) |
| Maximum pressure drop per pressure vessel (maximum 2 elements) | 30 psi (2.1 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty; pretreatment to remove free chlorine is recommended.
- Discard the permeate obtained during the first hour of operation.
- Use of this product does not by itself guarantee the removal of cysts and pathogens from water.
Private label and custom versions
The DuPont™ FilmTec™ XLE-2521 element is ideal for small commercial systems that require very low pressure operation and reduced energy consumption. Contact our team for commercial inquiries, customization options and technical support.
Ti serve questa membrana nel tuo impianto?