Filmtec · Nano Filtration
NF90
DuPont™ FilmTec™ NF90-4040 Nanofiltration Element The DuPont™ FilmTec™ NF90-4040 nanofiltration element is designed for commercial systems and offers high flux for high yields, low energy consumption that reduces operating costs, and long service life thanks to excellent cleanability. Key specifications include an active area of 82 ft² (7.6 m²), a permeate flow rate of 2,000 […]
DuPont™ FilmTec™ NF90-4040 Nanofiltration Element
The DuPont™ FilmTec™ NF90-4040 nanofiltration element is designed for commercial systems and offers high flux for high yields, low energy consumption that reduces operating costs, and long service life thanks to excellent cleanability. Key specifications include an active area of 82 ft² (7.6 m²), a permeate flow rate of 2,000 gpd (9.5 m³/d) and a stabilized salt rejection greater than 98.7%.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Part Number | 12096025 |
| Active area | 82 ft² (7.6 m²) |
| Applied pressure | 70 psi (4.8 bar) |
| Permeate flow rate | 2,000 gpd (9.5 m³/d) |
| Stabilized salt rejection | > 98.7% |
| Membrane type | Polypiperazine Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 40.0 in | 1,016 mm |
| Diameter (B) | 3.9 in | 99 mm |
| Diameter (C) | 0.75 in | 19 mm |
| D | 1.05 in | 27 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 600 psi (41 bar) |
| Maximum pressure drop | 15 psi (1.0 bar) |
| pH range (continuous operation) | 3–10 |
| pH range (short-term cleaning, 30 min) | 1–12 |
| Maximum feed flow rate | 16 gpm (3.6 m³/h) |
| Maximum Silt Density Index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered under warranty; removal of free chlorine by pretreatment is recommended prior to membrane exposure.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- Use of this product does not in itself guarantee the removal of cysts and pathogens from water.
Private label and custom versions
The DuPont™ FilmTec™ NF90-4040 element is ideal for demineralization applications in small commercial systems. Contact our team for commercial inquiries, customization options and technical support.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.