Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italien +39 0721 1797741 info@ultramarwater.com
NF90

Filmtec · Nano Filtration

NF90

DuPont™ FilmTec™ NF90-4040 Nanofiltration Element The DuPont™ FilmTec™ NF90-4040 nanofiltration element is designed for commercial systems and offers high flux for high yields, low energy consumption that reduces operating costs, and long service life thanks to excellent cleanability. Key specifications include an active area of 82 ft² (7.6 m²), a permeate flow rate of 2,000 […]

DuPont™ FilmTec™ NF90-4040 Nanofiltration Element

The DuPont™ FilmTec™ NF90-4040 nanofiltration element is designed for commercial systems and offers high flux for high yields, low energy consumption that reduces operating costs, and long service life thanks to excellent cleanability. Key specifications include an active area of 82 ft² (7.6 m²), a permeate flow rate of 2,000 gpd (9.5 m³/d) and a stabilized salt rejection greater than 98.7%.

Specifications

FeatureValue / Technical Data
Part Number12096025
Active area82 ft² (7.6 m²)
Applied pressure70 psi (4.8 bar)
Permeate flow rate2,000 gpd (9.5 m³/d)
Stabilized salt rejection> 98.7%
Membrane typePolypiperazine Thin-Film Composite
General specifications of the NF90-4040 element.

Dimensions

DimensionImperialMetric
Length (A)40.0 in1,016 mm
Diameter (B)3.9 in99 mm
Diameter (C)0.75 in19 mm
D1.05 in27 mm
Mechanical dimensions of the module.

Operating limits for design

Maximum operating temperature113°F (45°C)
Maximum operating pressure600 psi (41 bar)
Maximum pressure drop15 psi (1.0 bar)
pH range (continuous operation)3–10
pH range (short-term cleaning, 30 min)1–12
Maximum feed flow rate16 gpm (3.6 m³/h)
Maximum Silt Density Index (SDI)SDI 5
Free chlorine tolerance< 0.1 ppm

Important operation notes

  • Keep elements moist at all times after initial wetting.
  • Oxidation damage caused by free chlorine or other oxidizing agents is not covered under warranty; removal of free chlorine by pretreatment is recommended prior to membrane exposure.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • Use of this product does not in itself guarantee the removal of cysts and pathogens from water.

Private label and custom versions

The DuPont™ FilmTec™ NF90-4040 element is ideal for demineralization applications in small commercial systems. Contact our team for commercial inquiries, customization options and technical support.

Benötigen Sie diese Membran für Ihre Anlage?

Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.

Angebot anfordern

Ähnliche Membranen

Adresse

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italien