Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
Eco Platinum-440i

Filmtec · Brackish Water

Eco Platinum-440i

DuPont™ FilmTec™ Eco Platinum-440i Reverse Osmosis Element The DuPont™ FilmTec™ Eco Platinum-440i reverse osmosis element offers high salt rejection at low pressure, excellent rejection of silica, boron, nitrates, TOC and ammonium, and integrated iLEC™ interlocking endcaps that reduce operating costs and the risk of O-ring leaks. Key specifications include an active area of 440 ft² […]

Diametro
8″
Formato
8040

DuPont™ FilmTec™ Eco Platinum-440i Reverse Osmosis Element

The DuPont™ FilmTec™ Eco Platinum-440i reverse osmosis element offers high salt rejection at low pressure, excellent rejection of silica, boron, nitrates, TOC and ammonium, and integrated iLEC™ interlocking endcaps that reduce operating costs and the risk of O-ring leaks. Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 12,650 GPD (48 m³/d) and a stabilized salt rejection of 99.7%.

Specifications

FeatureValue / Technical data
Active area440 ft² (41 m²)
Feed spacer thickness28-LDP
Permeate flow rate12,650 GPD (48 m³/d)
Stabilized salt rejection99.7%
Minimum salt rejection99.4%
Membrane typePolyamide Thin-Film Composite
General specifications of the Eco Platinum-440i element.

Dimensions

DimensionImperialMetric
Net length (A)40.0 in1,016 mm
B DIA7.9 in201 mm
C DIA (ID)1.125 in ID29 mm ID
D0.5 in12.7 mm
Dimensions in inches (mm). 1 inch = 25.4 mm. Individual elements with iLEC™ endcaps measure 40.5 in (1,029 mm) in overall length.

Operating limits for design

Maximum operating temperature113°F (45°C)
Maximum operating pressure600 psi (41 bar)
Maximum pressure drop per element15 psi (1.0 bar)
Maximum pressure drop per pressure vessel (minimum 4 elements)50 psi (3.5 bar)
pH range (continuous operation)2–11
pH range (short-term cleaning, 30 min)1–13
Maximum feed flow rate75 gpm (17 m³/h)
Maximum feed silt density index (SDI)SDI 5
Free chlorine tolerance< 0.1 ppm

Important operation notes

  • Keep elements moist at all times after initial wetting.
  • The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
  • Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty.
  • Discard the permeate obtained during the first hour of operation.
  • Use of this product does not by itself guarantee the removal of cysts and pathogens from water; effectiveness depends on overall system design and maintenance.

Private label and custom versions

The DuPont™ FilmTec™ Eco Platinum-440i element is ideal for industrial process water, industrial water demineralization, boiler feed water, cooling tower water and municipal water purification. Contact our team for commercial inquiries, customization options and technical support.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Membrane simili

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia