Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
BW-4040-HR-ULTRAMAR-WATER

Ultramar Water · Brackish Water

BW-4040-HR-ULTRAMAR-WATER

BW-4040-HR brackish water reverse osmosis membrane The BW-4040-HR is a 4-inch spiral wound brackish water reverse osmosis membrane engineered for low or ultra-low pressure brackish water treatment applications. Delivering high rejection and high productivity, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational metrics include a permeate flow […]

Diametro
4″
Formato
4040

BW-4040-HR brackish water reverse osmosis membrane

The BW-4040-HR is a 4-inch spiral wound brackish water reverse osmosis membrane engineered for low or ultra-low pressure brackish water treatment applications. Delivering high rejection and high productivity, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational metrics include a permeate flow of 2,200 GPD (8 m³/day), an active membrane area of 90 ft² (8.4 m²), and a stabilized salt rejection of 99.7%.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
BW-4040-HR2,200 (8)90 (8.4)99.7%99.5%28 (0.7)225 psi / 2,000 ppm NaCl
1. All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelOverall Length (A)Permeate Tube Extension (B)Diameter (C)
BW-4040-HR40.0 (1016)1.05 (26.7)3.9 (99)
Dimensions in inches (mm). 1 inch = 25.4 mm. Permeate tube diameter is 0.75 in (19 mm).

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation2–11
pH Range for Cleaning1.2–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The BW-4040-HR is available under your brand. Contact our team for volumes, labeling and custom specifications.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Membrane simili

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia