Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
BW-4021-ULTRAMAR-WATER

Ultramar Water · Brackish Water

BW-4021-ULTRAMAR-WATER

BW-4021 brackish water reverse osmosis membrane The BW-4021 is a 4-inch spiral wound brackish water reverse osmosis membrane engineered for low or ultra-low pressure brackish water treatment applications. Delivering high productivity and low pressure operation, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational metrics include a permeate […]

Diametro
4″
Formato
4021

BW-4021 brackish water reverse osmosis membrane

The BW-4021 is a 4-inch spiral wound brackish water reverse osmosis membrane engineered for low or ultra-low pressure brackish water treatment applications. Delivering high productivity and low pressure operation, this element is ideal for original equipment manufacturers (OEMs), system builders, and service centers. Key operational metrics include a permeate flow of 900 GPD (3.4 m³/day), an active membrane area of 36 ft² (3.3 m²), and a stabilized salt rejection of 99.6%.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
BW-4021900 (3.4)36 (3.3)99.6%99.4%28 (0.7)225 psi / 2,000 ppm NaCl
1. All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelOverall Length (A)Permeate Tube Extension (B)Diameter (C)
BW-402121.0 (533)1.05 (26.7)3.9 (99)
Dimensions in inches (mm). 1 inch = 25.4 mm. Permeate tube diameter is 0.75 in (19 mm).

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation2–11
pH Range for Cleaning1.2–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The BW-4021 is available under your brand. Contact our team for volumes, labeling and custom specifications.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Membrane simili

Indirizzo

Via Caduti sul Lavoro, 6