Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italien +39 0721 1797741 info@ultramarwater.com
ULP-8040-400-HR-ULTRAMAR-WATER

Ultramar Water · Ultra Low Pressure

ULP-8040-400-HR-ULTRAMAR-WATER

ULP-8040-400-HR Brackish Water Membrane The ULP-8040-400-HR brackish water membrane is an 8-inch spiral wound element designed for brackish water treatment. Its low-pressure, high-productivity design is intended for applications operating under low or ultra-low pressure conditions. With a permeate flow of 10,800 GPD (41 m³/day), an active membrane area of 400 ft² (37 m²), and a […]

Durchmesser
8″
Format
8040

ULP-8040-400-HR Brackish Water Membrane

The ULP-8040-400-HR brackish water membrane is an 8-inch spiral wound element designed for brackish water treatment. Its low-pressure, high-productivity design is intended for applications operating under low or ultra-low pressure conditions.

With a permeate flow of 10,800 GPD (41 m³/day), an active membrane area of 400 ft² (37 m²), and a stabilized salt rejection of 99.4%, this membrane can be considered for reverse osmosis systems designed by OEMs, plant builders and industrial water treatment professionals.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
ULP-8040-400-HR10,800 (41)400 (37)99.4%99.2%28 (0.7)150 psi / 2,000 ppm NaCl
All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. Permeate flow for a single element may vary ±15%.

Dimensions

ModelABC
ULP-8040-400-HR40.0 (1016)1.125 (29)7.9 (201)
Dimensions in inches (mm). 1 inch = 25.4 mm.

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation2–11
pH Range for Cleaning2–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

Ultramar Water supports OEMs and water treatment system builders in identifying membrane solutions for their applications. Contact our team to discuss your project requirements and available supply options.

Contact Ultramar Water to request further information.