Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italien +39 0721 1797741 info@ultramarwater.com
MB-PRO-95 TR

Integratec

MB-PRO-95 TR

DuPont™ IntegraTec™ MB PRO 95 TR pressurized ultrafiltration module The DuPont™ IntegraTec™ MB PRO 95 TR pressurized ultrafiltration module from the P Series is specifically designed for integration into T-Rack™ systems. It uses innovative Multibore™ PRO PES fiber technology, delivering outstanding physical and chemical resistance, an increased active filtration area to minimize footprint, and an […]

DuPont™ IntegraTec™ MB PRO 95 TR pressurized ultrafiltration module

The DuPont™ IntegraTec™ MB PRO 95 TR pressurized ultrafiltration module from the P Series is specifically designed for integration into T-Rack™ systems. It uses innovative Multibore™ PRO PES fiber technology, delivering outstanding physical and chemical resistance, an increased active filtration area to minimize footprint, and an end-cap design optimized for scalability. Key specifications include an active membrane area of 95 m² (1,023 ft²) and a nominal membrane pore size of 0.02 μm.

Specifications

FeatureValue / Technical data
Part Number / GMIDIN-5122/12071531
Filtration modeIn-Out Pressurized
Membrane typeMultibore™ PRO
Membrane materialPESM
Nominal pore size0.02 μm
Module operating processDead-end
Housing materialPVC-U, white
Active membrane area95 m² (1,023 ft²)
General specifications of the MB PRO 95 TR module.

Dimensions

DimensionMetricImperial
Module length including T-connectors (L)2,101 mm82.7 in
Module diameter (D)250 mm9.8 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1-40 °C (34-104 °F)
Operating pH3-11
Cleaning pH1-13
Maximum operating pressure (inlet pressure)5 bar (73 psi)
Maximum temperature change rate5 °C/min (9 °F/min)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
Free chlorine tolerance (NaOCl exposure)≤ 250,000 ppm × h (at pH ≥ 9.5)

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ Pressurized UF In-Out P Series Assembly Instructions for T-Rack™ Manual (Form No. 45-D02230-en).
  • During extended system shutdowns, introduce a preservation solution to control biological growth, following the dedicated manual.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ MB PRO 95 TR module can be integrated into advanced rack configurations for T-Rack™ systems. Contact our team for commercial enquiries, customization options and technical support.

Benötigen Sie diese Membran für Ihre Anlage?

Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.

Angebot anfordern

Adresse

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italien