Filmtec · Extra Low Energy
XLE-440
DuPont™ FilmTec™ XLE-440 Brackish Water Reverse Osmosis Element The DuPont™ FilmTec™ XLE-440 brackish water reverse osmosis element offers good salt rejection with exceptionally low energy consumption, ensuring excellent rejection of silica, nitrates and ammonium, along with long service life and high chemical tolerance thanks to a wide cleaning pH range (1–13). Key specifications include an […]
- Durchmesser
- 8″
- Format
- 8040
DuPont™ FilmTec™ XLE-440 Brackish Water Reverse Osmosis Element
The DuPont™ FilmTec™ XLE-440 brackish water reverse osmosis element offers good salt rejection with exceptionally low energy consumption, ensuring excellent rejection of silica, nitrates and ammonium, along with long service life and high chemical tolerance thanks to a wide cleaning pH range (1–13). Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 14,000 GPD (53 m³/d) and a stabilized salt rejection of 99.0%.
Specifications
| Feature | Value / Technical data |
|---|---|
| Active area | 440 ft² (41 m²) |
| Feed spacer thickness | 28 mil |
| Permeate flow rate | 14,000 GPD (53 m³/d) |
| Stabilized salt rejection | 99.0% |
| Minimum salt rejection | 97.0% |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 40.0 in | 1,016 mm |
| B DIA | 7.9 in | 201 mm |
| C DIA (ID) | 1.5 in ID | 38 mm ID |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 600 psi (41 bar) |
| Maximum pressure drop per element | 15 psi (1.0 bar) |
| Maximum pressure drop per pressure vessel (minimum 4 elements) | 50 psi (3.5 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum feed flow rate | 75 gpm (17 m³/h) |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty; DuPont recommends removing residual free chlorine by pretreatment.
- Discard the permeate obtained during the first hour of operation.
- Use of this product does not by itself guarantee the removal of cysts and pathogens from water.
Private label and custom versions
The DuPont™ FilmTec™ XLE-440 element is ideal for municipal drinking water production and industrial process water applications. Contact our team for commercial inquiries, customization options and technical support.
Benötigen Sie diese Membran für Ihre Anlage?
Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.
Ähnliche Membranen