DuPont™ FilmTec™ Seamaxx-440i Seawater Reverse Osmosis Element The DuPont™ FilmTec™ Seamaxx-440i seawater reverse osmosis element is designed to deliver very high permeate flow, enabling significant energy savings and reducing system capital costs. It features iLEC™ interlocking endcaps to reduce operating costs and the risk of O-ring leaks. Key specifications include an active area of 440 […]
- Durchmesser
- 8″
- Format
- 8040
DuPont™ FilmTec™ Seamaxx-440i Seawater Reverse Osmosis Element
The DuPont™ FilmTec™ Seamaxx-440i seawater reverse osmosis element is designed to deliver very high permeate flow, enabling significant energy savings and reducing system capital costs. It features iLEC™ interlocking endcaps to reduce operating costs and the risk of O-ring leaks. Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 9,050 gpd (34.2 m³/d) at 600 psi (and up to 17,000 gpd at 800 psi) and a stabilized salt rejection of 99.47%.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Active area | 440 ft² (41 m²) |
| Feed spacer thickness | 28 mil |
| Permeate flow rate (at 600 psi / 4.1 MPa) | 9,050 gpd (34.2 m³/d) |
| Projected permeate flow rate (at 800 psi / 5.5 MPa) | 17,000 gpd (64.4 m³/d) |
| Stabilized boron rejection (at 600 psi) | 81.8% |
| Stabilized salt rejection (at 600 psi) | 99.47% |
| Minimum salt rejection (at 600 psi) | 99.25% |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Net length (A) | 40.0 in | 1,016 mm |
| Diameter (B) | 7.9 in | 201 mm |
| Inner diameter (C) | 1.125 in ID | 29 mm ID |
| D (D) | 0.5 in | 12.7 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 1,200 psi (83 bar) |
| Maximum pressure drop per element | 15 psi (1.0 bar) |
| Maximum pressure drop per pressure vessel (minimum 4 elements) | 50 psi (3.5 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum Silt Density Index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered under warranty.
- Permeate obtained from the first hour of operation should be discarded.
- Use of this product does not in itself guarantee the removal of cysts and pathogens from water; effectiveness depends on the overall system design and maintenance.
Private label and custom versions
The DuPont™ FilmTec™ Seamaxx-440i element is ideal for seawater desalination in municipal and industrial applications with high energy costs. Contact our team for commercial inquiries, customization options and technical support.