NF-8040-AR-34-ULTRAMAR-WATER

Ultramar Water · Nano Filtration

NF-8040-AR-34-ULTRAMAR-WATER

NF-8040-AR(34) acid-resisting nanofiltration membrane The NF-8040-AR(34) is an 8-inch spiral wound acid-resisting nanofiltration element (down to pH 0), specifically designed for lithium extraction and acid recovery. Offering high selectivity and resistance in acidic environments, this element is ideal for advanced industrial applications. Key operational data includes a permeate flow of 7,000 GPD (26.5 m³/day), an […]

Diameter
8″
Format
8040

NF-8040-AR(34) acid-resisting nanofiltration membrane

The NF-8040-AR(34) is an 8-inch spiral wound acid-resisting nanofiltration element (down to pH 0), specifically designed for lithium extraction and acid recovery. Offering high selectivity and resistance in acidic environments, this element is ideal for advanced industrial applications. Key operational data includes a permeate flow of 7,000 GPD (26.5 m³/day), an active membrane area of 370 ft² (34 m²), and a stabilized salt rejection of 95%.

Specifications

ModelPermeate Flow GPD (m³/day)Active Membrane Area ft² (m²)Stabilized Salt RejectionMinimum Salt RejectionFeed Spacer mil (mm)Test Conditions
NF-8040-AR(34)7,000 (26.5)370 (34)95%93%34 (0.85)110 psi / 2,000 ppm MgSO₄
1. All performance data are collected at 25°C (77°F), pH 7.5 and 15% recovery rate. 2. Permeate flow for a single element may vary ±15%.

Dimensions

ModelABC
NF-8040-AR(34)40.0 (1016)1.125 (29)7.9 (201)
Dimensions in inches (mm). 1 inch = 25.4 mm.

Operating limits for design

Maximum Operating Temperature45°C (113°F)
Maximum Operating Pressure600 psi (41 bar)
Maximum Pressure Drop (single element)15 psi (1.0 bar)
pH Range for Continuous Operation0–11
pH Range for Cleaning0–12
Chlorine Tolerance< 0.1 ppm
Maximum Feed SDI5

Important operation notes

  • Discard the permeate produced during the first hour of use.
  • Keep elements moist at all times after initial wetting.
  • During prolonged shutdowns, store elements in a preservative solution to prevent biological growth, and rinse it out before use.
  • The OEM is responsible for the effects of incompatible chemicals and lubricants on the elements.
  • Failure to follow these operating limits voids the limited warranty.

Private label and custom versions

The NF-8040-AR(34) is available under your brand. Contact our team for volumes, labeling and custom specifications.

Need this membrane in your system?

We can adapt it to your plant, label it with your brand and support you through installation.

Request a quote

Similar membranes

Address

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italy

Telephone

+39 0721 1797741