Integratec
MB-40
DuPont™ IntegraTec™ MB 40 Pressurized Ultrafiltration Module The DuPont™ IntegraTec™ MB 40 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 40 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance and a unique design for high solids loads. Designed for open-platform applications on custom skids, […]
DuPont™ IntegraTec™ MB 40 Pressurized Ultrafiltration Module
The DuPont™ IntegraTec™ MB 40 pressurized ultrafiltration module (formerly known as dizzer XL 1.5 MB 40 W) from the P Series uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance and a unique design for high solids loads. Designed for open-platform applications on custom skids, it is ideal for height-restricted or containerized solutions. Key specifications include an active membrane area of 40 m² (431 ft²) and a nominal membrane pore size of 0.02 μm.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Part Number / GMID | IN-0069/12071517 |
| Filtration mode | In-Out Pressurized |
| Membrane type | Multibore |
| Membrane material | PESM |
| Nominal pore size | 0.02 μm |
| Module operating process | Dead-end |
| Housing material | PVC-U, white |
| Active membrane area | 40 m² (431 ft²) |
Dimensions
| Dimension | Metric | Imperial |
|---|---|---|
| Module length (L) | 1,485 ± 1.5 mm | 58.5 in |
| Distance between top/bottom feed ports (L1) | 1,599 ± 3.0 mm | 63.0 in |
| Length with end caps (L2) | 1,679 ± 3.0 mm | 66.1 in |
| Module diameter (A) | 250 ± 1.5 mm | 9.8 in |
| Distance from top feed port to filtrate port (B) | 190 ± 1.5 mm | 7.5 in |
| Maximum end cap coupling outer diameter (C) | 295 mm | 11.6 in |
| Filtrate / backwash port (D) | 50.8 mm | 2 in |
Operating limits for design
| Operating temperature range | 1–40°C (34–104°F) |
| Operating pH | 3–11 |
| Cleaning pH | 1–13 |
| Maximum inlet pressure | 5 bar (73 psi) |
| Maximum temperature change rate | 5°C/min (9°F/min) |
| Maximum allowable pressure change rate | 0.5 bar/s (7.3 psi/s) |
| NaOCl exposure (free chlorine tolerance) | ≤ 250,000 ppm×h (at pH ≥ 9.5) |
Important operation notes
- Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
- For assembly, refer to the dedicated DuPont™ IntegraTec™ Pressurized UF In-Out P Series Modules for Open Platforms Assembly Instructions (Form No. 45-D02231-en).
- During prolonged system shutdowns, introduce a preservation solution to control biological growth, following the dedicated manual.
- Modules certified for drinking water require specific conditioning procedures before production.
- Failure to strictly follow the operating limits and guidelines voids any warranty.
Private label and custom versions
The DuPont™ IntegraTec™ MB 40 module can be integrated into customized open-platform solutions. Contact our team for commercial inquiries, customization options and technical support.
Need this membrane in your system?