Integratec
XP-77
DuPont™ IntegraTec™ XP 77 PVDF Ultrafiltration Module The DuPont™ IntegraTec™ XP 77 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2880XP) from the P Series uses advanced XP™ hydrophilic PVDF hollow fiber technology, providing superior fouling and chlorine resistance, high permeability and excellent removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on […]
DuPont™ IntegraTec™ XP 77 PVDF Ultrafiltration Module
The DuPont™ IntegraTec™ XP 77 pressurized ultrafiltration module (formerly known as DuPont™ IntegraFlux™ SFD-2880XP) from the P Series uses advanced XP™ hydrophilic PVDF hollow fiber technology, providing superior fouling and chlorine resistance, high permeability and excellent removal of colloidal particulates, bacteria and viruses. Designed for open-platform applications on custom skids, it offers a high active filtration area to maximize productivity. Key specifications include an active membrane area of 77 m² (829 ft²) and a nominal pore size of 0.03 μm.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Part No / GMID | 12091620 |
| Filtration mode | Out-In Pressurized |
| Membrane type | Hollow fiber |
| Membrane material | PVDF (Polyvinylidene Fluoride) |
| Nominal pore size | 0.03 μm |
| Module operating process | Dead-end |
| Other wetted components | Polyurethane, uPVC, EPDM and ABS |
| Active membrane area | 77 m² (829 ft²) |
Dimensions
| Dimension | Metric | Imperial |
|---|---|---|
| Overall module length (L) | 2,363 ± 3.0 mm | 93.0 ± 0.1 in |
| Module length (L1) | 2,000 ± 1.5 mm | 78.7 ± 0.1 in |
| Module length (L2) | 2,133 ± 3.0 mm | 84.0 ± 0.1 in |
| Module length (L3) | 2,323 ± 3.0 mm | 91.4 ± 0.1 in |
| Module diameter (D) | 225 mm | 8.9 in |
| Module width (W1) | 180 mm | 7.1 in |
| Module width (W2) | 342 mm | 13.5 in |
| Feed / filtrate port DN50 (F) | 51 mm | 2.0 in |
Operating limits for design
| Operating temperature range | 1–40°C (34–104°F) |
| Operating pH | 2–11 |
| Cleaning pH | 2–12 |
| Maximum inlet pressure | 6.25 bar at 20°C (90.7 psi) |
| Maximum allowable pressure change rate | 0.5 bar/s (7.3 psi/s) |
| NaOCl exposure (free chlorine tolerance) | ≤ 1,500,000 ppm×h |
Important operation notes
- Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
- For assembly, refer to the dedicated DuPont™ IntegraTec™ PVDF-UF Out-In P Series Modules for Open Platforms Assembly Manual (Form No. 45-D02507-en).
- During prolonged system shutdowns, introduce a preservation solution to control biological growth.
- Modules certified for drinking water require specific conditioning procedures before production.
- Failure to strictly follow the operating limits and guidelines voids any warranty.
Private label and custom versions
The DuPont™ IntegraTec™ XP 77 module can be integrated into customized open-platform solutions. Contact our team for commercial inquiries, customization options and technical support.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.