Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
XP-77-IP

Integratec

XP-77-IP

DuPont™ IntegraTec™ XP 77 IP PVDF Ultrafiltration Module The DuPont™ IntegraTec™ XP 77 IP pressurized ultrafiltration module (formerly known as DuPont™ IntegraPac™ IPD-77XP) from the P Series is specifically designed for installation in IntegraPac IP racks, featuring an innovative end connection design for direct coupling and scalability. It uses advanced XP™ hydrophilic PVDF hollow fiber […]

DuPont™ IntegraTec™ XP 77 IP PVDF Ultrafiltration Module

The DuPont™ IntegraTec™ XP 77 IP pressurized ultrafiltration module (formerly known as DuPont™ IntegraPac™ IPD-77XP) from the P Series is specifically designed for installation in IntegraPac IP racks, featuring an innovative end connection design for direct coupling and scalability. It uses advanced XP™ hydrophilic PVDF hollow fiber technology, providing superior fouling and chlorine resistance, high permeability and excellent removal of colloidal particulates, bacteria and viruses. Key specifications include an active membrane area of 77 m² (829 ft²) and a nominal pore size of 0.03 μm.

Specifications

FeatureValue / Technical Data
Part No / GMID12091629
Filtration modeOut-In Pressurized
Membrane typeHollow fiber
Membrane materialPVDF (Polyvinylidene Fluoride)
Nominal pore size0.03 μm
Module operating processDead-end
Other wetted componentsPolyurethane, uPVC, EPDM and ABS
Active membrane area77 m² (829 ft²)
General specifications of the XP 77 IP module.

Dimensions

DimensionMetricImperial
Overall module length (L)2,491 ± 3.0 mm98.1 ± 0.1 in
Module length (L1)2,000 ± 1.5 mm78.7 ± 0.1 in
Module length (L2)2,192 ± 3.0 mm86.3 ± 0.1 in
Module length (L3)2,367 ± 3.0 mm93.2 ± 0.1 in
Module diameter (D)225 mm8.9 in
Module width (W1)360 mm14.2 in
Module width (W2)342 mm13.5 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1–40°C (34–104°F)
Operating pH2–11
Cleaning pH2–12
Maximum inlet pressure6.25 bar at 20°C (90.7 psi)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
NaOCl exposure (free chlorine tolerance)≤ 1,500,000 ppm×h

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ PVDF-UF Out-In P Series IntegraPac™ Rack Assembly Manual (Form No. 45-D01776-en).
  • During prolonged system shutdowns, introduce a preservation solution to control biological growth.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ XP 77 IP module can be integrated into customized rack configurations for IntegraPac IP systems. Contact our team for commercial inquiries, customization options and technical support.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia