Integratec
XP-51-IP-IG
DuPont™ IntegraTec™ XP 51 IP IG PVDF Ultrafiltration Module The DuPont™ IntegraTec™ XP 51 IP IG pressurized ultrafiltration module (formerly known as DuPont™ IntegraPac™ IP-51XP) from the P Series is specifically designed for installation in IntegraPac IP racks, featuring an innovative end connection design for direct coupling and scalability. It uses advanced XP™ hydrophilic PVDF […]
DuPont™ IntegraTec™ XP 51 IP IG PVDF Ultrafiltration Module
The DuPont™ IntegraTec™ XP 51 IP IG pressurized ultrafiltration module (formerly known as DuPont™ IntegraPac™ IP-51XP) from the P Series is specifically designed for installation in IntegraPac IP racks, featuring an innovative end connection design for direct coupling and scalability. It uses advanced XP™ hydrophilic PVDF hollow fiber technology, providing superior fouling and chlorine resistance, excellent permeability and high removal of colloidal particulates, bacteria and viruses. Key specifications include an active membrane area of 51 m² (549 ft²) and a nominal pore size of 0.03 μm.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Part No / GMID | 12091626 |
| Filtration mode | Out-In Pressurized |
| Membrane type | Hollow fiber |
| Membrane material | PVDF (Polyvinylidene Fluoride) |
| Nominal pore size | 0.03 μm |
| Module operating process | Dead-end |
| Other wetted components | Polyurethane, uPVC, EPDM and ABS |
| Active membrane area | 51 m² (549 ft²) |
Dimensions
| Dimension | Metric | Imperial |
|---|---|---|
| Overall module length (L) | 1,991 ± 3.0 mm | 78.4 ± 0.1 in |
| Module length (L1) | 1,500 ± 1.5 mm | 59.1 ± 0.1 in |
| Module length (L2) | 1,692 ± 3.0 mm | 66.6 ± 0.1 in |
| Module length (L3) | 1,867 ± 3.0 mm | 73.5 ± 0.1 in |
| Module diameter (D) | 225 mm | 8.9 in |
| Module width (W1) | 360 mm | 14.2 in |
| Module width (W2) | 342 mm | 13.5 in |
Operating limits for design
| Operating temperature range | 1–40°C (34–104°F) |
| Operating pH | 2–11 |
| Cleaning pH | 2–12 |
| Maximum inlet pressure | 6.25 bar at 20°C (90.7 psi) |
| Maximum allowable pressure change rate | 0.5 bar/s (7.3 psi/s) |
| NaOCl exposure (free chlorine tolerance) | ≤ 1,500,000 ppm×h |
Important operation notes
- Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
- For assembly, refer to the dedicated DuPont™ IntegraTec™ PVDF-UF Out-In P Series IntegraPac™ IP Rack Assembly Manual (Form No. 45-D01776-en).
- During prolonged system shutdowns, introduce a preservation solution to control biological growth.
- Modules certified for drinking water require specific conditioning procedures before production.
- Failure to strictly follow the operating limits and guidelines voids any warranty.
Private label and custom versions
The DuPont™ IntegraTec™ XP 51 IP IG module can be integrated into customized rack configurations for high-recovery applications. Contact our team for commercial inquiries, customization options and technical support.
Ti serve questa membrana nel tuo impianto?
Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.