Via Caduti sul Lavoro, 6, 61032 Fano (PU), Italia +39 0721 1797741 info@ultramarwater.com
MB-60 TR S

Integratec

MB-60 TR S

DuPont™ IntegraTec™ MB 60 TR S Pressurized Ultrafiltration Module The DuPont™ IntegraTec™ MB 60 TR S pressurized ultrafiltration module (formerly known as dizzer XL 0.9 MB 60 ST) from the P Series is specifically designed for integration into T-Rack™ S systems. It uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance, a […]

DuPont™ IntegraTec™ MB 60 TR S Pressurized Ultrafiltration Module

The DuPont™ IntegraTec™ MB 60 TR S pressurized ultrafiltration module (formerly known as dizzer XL 0.9 MB 60 ST) from the P Series is specifically designed for integration into T-Rack™ S systems. It uses advanced Multibore™ PES fiber technology, providing exceptional physical and chemical resistance, a unique design for high solids loads and an innovative end connection system for simple, scalable assembly. Key specifications include an active membrane area of 60 m² (646 ft²) and a nominal membrane pore size of 0.02 μm.

Specifications

FeatureValue / Technical Data
Part Number / GMIDIN-5102/12071528
Filtration modeIn-Out Pressurized
Membrane typeMultibore™
Membrane materialPESM
Nominal pore size0.02 μm
Module operating processDead-end
Housing materialPVC-U, white
Active membrane area60 m² (646 ft²)
General specifications of the MB 60 TR S module.

Dimensions

DimensionMetricImperial
Module length including T-connectors (L)1,879 mm74.0 in
Module diameter (D)250 mm9.8 in
Mechanical dimensions of the module.

Operating limits for design

Operating temperature range1–40°C (34–104°F)
Operating pH3–11
Cleaning pH1–13
Maximum inlet pressure5 bar (73 psi)
Maximum temperature change rate5°C/min (9°F/min)
Maximum allowable pressure change rate0.5 bar/s (7.3 psi/s)
NaOCl exposure (free chlorine tolerance)≤ 250,000 ppm×h (at pH ≥ 9.5)

Important operation notes

  • Avoid sudden pressure changes during start-up, operation, shutdown or cleaning sequences to prevent membrane damage (maximum allowable change 0.5 bar/s).
  • For assembly, refer to the dedicated DuPont™ IntegraTec™ Pressurized UF In-Out P Series Assembly Instructions for T-Rack™ Manual (Form No. 45-D02230-en).
  • During prolonged system shutdowns, introduce a preservation solution to control biological growth, following the dedicated manual.
  • Modules certified for drinking water require specific conditioning procedures before production.
  • Failure to strictly follow the operating limits and guidelines voids any warranty.

Private label and custom versions

The DuPont™ IntegraTec™ MB 60 TR S module can be integrated into customized rack configurations for T-Rack™ S systems. Contact our team for commercial inquiries, customization options and technical support.

Ti serve questa membrana nel tuo impianto?

Possiamo adattarla al tuo impianto, personalizzarla con il tuo marchio e seguirti nell'installazione.

Richiedi un preventivo

Indirizzo

Via Caduti sul Lavoro, 6
61032 Fano (PU), Italia