Filmtec · Brackish Water
TW30-1812-100HR
DuPont™ FilmTec™ TW30-1812-100HR Residential Reverse Osmosis Element The DuPont™ FilmTec™ TW30-1812-100HR residential reverse osmosis element offers a superior balance between the highest available flow and high-end rejection, making it ideal for residential applications with low feed pressure. Thanks to a new advanced membrane chemistry, it achieves a stabilized salt rejection of 98%. Key specifications include […]
- Durchmesser
- 1,8″
- Format
- 1812
DuPont™ FilmTec™ TW30-1812-100HR Residential Reverse Osmosis Element
The DuPont™ FilmTec™ TW30-1812-100HR residential reverse osmosis element offers a superior balance between the highest available flow and high-end rejection, making it ideal for residential applications with low feed pressure. Thanks to a new advanced membrane chemistry, it achieves a stabilized salt rejection of 98%. Key specifications include a permeate flow rate of 100 GPD (15.8 l/h) at an applied pressure of 50 psig (3.4 bar).
Specifications
| Feature | Value / Technical data |
|---|---|
| Permeate flow rate | 100 GPD (15.8 l/h) |
| Stabilized salt rejection | 98% |
| Minimum salt rejection | 96.0% |
| Applied pressure | 50 psig (3.4 bar) |
| Membrane type | Spiral-wound element with polyamide thin-film composite membrane |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 11.74 in | 298 mm |
| B | 0.875 in | 22.2 mm |
| C | 0.68 in | 17 mm |
| D | 1.75 in | 44.5 mm |
| E | 9.4 in | 239 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 150 psig (10 bar) |
| Maximum feed flow rate | 2.0 gpm (7.6 lpm) |
| pH range (continuous operation) | 2–11 |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Flushing elements for 24 hours before first use is recommended to meet NSF/ANSI 58.
- Discard the first full tank of permeate; do not use it for drinking or food preparation.
- Keep elements moist at all times after initial wetting.
- To prevent biological growth during prolonged shutdowns, immersing elements in a preservative solution is recommended.
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty.
Private label and custom versions
The DuPont™ FilmTec™ TW30-1812-100HR element is optimized for integration into low-pressure residential water purification systems. Contact our team for commercial inquiries, customization options and technical support.
DuPont™ FilmTec™ TW30-1812-100HR Residential Reverse Osmosis Element
The DuPont™ FilmTec™ TW30-1812-100HR residential reverse osmosis element offers a superior balance between the highest available flow and high-end rejection, making it ideal for residential applications with low feed pressure. Thanks to a new advanced membrane chemistry, it achieves a stabilized salt rejection of 98%. Key specifications include a permeate flow rate of 100 GPD (15.8 l/h) at an applied pressure of 50 psig (3.4 bar).
Specifications
| Feature | Value / Technical data |
|---|---|
| Permeate flow rate | 100 GPD (15.8 l/h) |
| Stabilized salt rejection | 98% |
| Minimum salt rejection | 96.0% |
| Applied pressure | 50 psig (3.4 bar) |
| Membrane type | Spiral-wound element with polyamide thin-film composite membrane |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 11.74 in | 298 mm |
| B | 0.875 in | 22.2 mm |
| C | 0.68 in | 17 mm |
| D | 1.75 in | 44.5 mm |
| E | 9.4 in | 239 mm |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 150 psig (10 bar) |
| Maximum feed flow rate | 2.0 gpm (7.6 lpm) |
| pH range (continuous operation) | 2–11 |
| Maximum feed silt density index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Flushing elements for 24 hours before first use is recommended to meet NSF/ANSI 58.
- Discard the first full tank of permeate; do not use it for drinking or food preparation.
- Keep elements moist at all times after initial wetting.
- To prevent biological growth during prolonged shutdowns, immersing elements in a preservative solution is recommended.
- Oxidation damage caused by free chlorine or other oxidizing agents is not covered by the warranty.
Private label and custom versions
The DuPont™ FilmTec™ TW30-1812-100HR element is optimized for integration into low-pressure residential water purification systems. Contact our team for commercial inquiries, customization options and technical support.
Benötigen Sie diese Membran für Ihre Anlage?
Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.