Filmtec · Sea Water
Seamaxx-440
DuPont™ FilmTec™ Seamaxx-440 Seawater Reverse Osmosis Element The DuPont™ FilmTec™ Seamaxx-440 seawater reverse osmosis element is designed to deliver very high permeate flow, enabling significant energy savings and reducing system capital costs. Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 9,050 gpd (34.2 m³/d) at 600 psi […]
- Durchmesser
- 8″
- Format
- 8040
DuPont™ FilmTec™ Seamaxx-440 Seawater Reverse Osmosis Element
The DuPont™ FilmTec™ Seamaxx-440 seawater reverse osmosis element is designed to deliver very high permeate flow, enabling significant energy savings and reducing system capital costs. Key specifications include an active area of 440 ft² (41 m²), a permeate flow rate of 9,050 gpd (34.2 m³/d) at 600 psi (and up to 17,000 gpd at 800 psi) and a stabilized salt rejection of 99.47%.
Specifications
| Feature | Value / Technical Data |
|---|---|
| Active area | 440 ft² (41 m²) |
| Feed spacer thickness | 28 mil |
| Permeate flow rate (at 600 psi / 4.1 MPa) | 9,050 gpd (34.2 m³/d) |
| Projected permeate flow rate (at 800 psi / 5.5 MPa) | 17,000 gpd (64.4 m³/d) |
| Stabilized boron rejection (at 600 psi) | 81.8% |
| Stabilized salt rejection (at 600 psi) | 99.47% |
| Minimum salt rejection (at 600 psi) | 99.25% |
| Membrane type | Polyamide Thin-Film Composite |
Dimensions
| Dimension | Imperial | Metric |
|---|---|---|
| Length (A) | 40.0 in | 1,016 mm |
| Diameter (B) | 7.9 in | 201 mm |
| Inner diameter (C) | 1.125 in ID | 29 mm ID |
Operating limits for design
| Maximum operating temperature | 113°F (45°C) |
| Maximum operating pressure | 1,200 psi (83 bar) |
| Maximum pressure drop per element | 15 psi (1.0 bar) |
| Maximum pressure drop per pressure vessel (minimum 4 elements) | 50 psi (3.5 bar) |
| pH range (continuous operation) | 2–11 |
| pH range (short-term cleaning, 30 min) | 1–13 |
| Maximum Silt Density Index (SDI) | SDI 5 |
| Free chlorine tolerance | < 0.1 ppm |
Important operation notes
- Keep elements moist at all times after initial wetting.
- The maximum temperature for continuous operation above pH 10 is 95°F (35°C).
- The presence of free chlorine and other oxidizing agents causes oxidation damage that is not covered under warranty.
- Permeate obtained from the first hour of operation should be discarded.
- Use of this product does not in itself guarantee the removal of cysts and pathogens from water; effectiveness depends on the overall system design and maintenance.
Private label and custom versions
The DuPont™ FilmTec™ Seamaxx-440 element can be integrated into desalination plants for municipal and industrial applications, particularly in installations with high energy costs. Contact our team for commercial inquiries, customization options and technical support.
Benötigen Sie diese Membran für Ihre Anlage?
Wir passen sie an Ihre Anlage an, versehen sie mit Ihrer Marke und begleiten Sie bei der Installation.